Hydrogen embrittlment usually comes from plating chrome or anti corrosion layers such as zinc or cadmium.

It is standard to bake the bolts at about 600f after plating to remove the hydrogen

May have been hard if they did not have a 18 foot long oven

25 posted on 03/27/2013 10:26:55 AM PDT by rdcbn
[ Post Reply | Private Reply | To 18 | View Replies ]


To: rdcbn

Not that hard to contract out. Friend of mine works in a place with an industrial oven several hundred feet long.


30 posted on 03/27/2013 10:49:26 AM PDT by Hillarys Gate Cult (Liberals make unrealistic demands on reality and reality doesn't oblige them.)